FIRE PROTECTION CONSULTING

IFAB is specialized in fire protection consulting. For this purpose, we offer fire protection expert opinions, fire protection concepts, fire protection planning and verification services for buildings as well as for regulated and unregulated special structures. The fire protection requirements are covered by the regulations and measures of the building code. The individual measures are bundled in a holistic fire protection concept or fire protection verification as follows:

preventive fire protection / fire prevention, (dann neue Zeile und folgende Auflistung: - structural fire safety , technical and plant-specific fire safety, - organisational fire safety. (dann neues separates Kästchen): fire-fighting / fire protection

fire prevention

Implementing these regulations is one of the standard tasks of our employees. Regulated and unregulated special buildings or buildings with above-average risk often require a special approach. This is necessary, for example, if the building or parts of it are not covered by regulations or if special design, monument protection and architectural concepts are to be implemented. Realizing the objectives of fire protection in spite of this is a major focus of our consulting services. With the experience gained from more than 1800 real fire tests, we are able to develop efficient and cost-optimized solutions. Concert halls, high-rise buildings, retail outlets, hospitals, laboratories, high-bay warehouses and listed buildings are typical examples of the challenges IFAB successfully meets.


To many industrial buildings and applications, the rules of the applicable law cannot be applied or can only be applied inadequately. Particularly high risks or valuable investments often require customized fire protection solutions. The conception, planning and support during the realization of these solutions are just as much part of our range of services as the proof in individual cases for their load-bearing capacity. For this purpose, IFAB uses contemporary engineering methods and backs them up with CFD simulations or real fire tests.

fire safety concepts help to implement the requirements of building law and serve to reduce the risk of fire and its effects to an acceptable level. IFAB prepares fire safety concepts, fire protection certificate and carries out fire safety planning on the basis of generally accepted building law principles. We have a unique collection of results from real fire tests and are thus able to comprehensively evaluate and apply measures of preventive and especially of plant fire protection. The concepts we develop are therefore not only based on theoretical principles, but also incorporate the results of more than 1800 real fire tests.

The creation of sophisticated fire safety concepts requires the holistic consideration of all measures of organizational, preventive and defensive fire protection. We offer support and supervision throughout the entire approval and planning process. Architectural and design aspects, protection of historical monuments, life cycle costs and technical reliability are taken into account as required. Together with clients and authorities, we ensure an accepted, yet cost-optimized execution and implementation of fire safety concepts.


If unconventional ideas are required for challenging objects, such as atriums, glass facades, special buildings in existing structures, metro stations and listed buildings, we are able to develop protection-goal-oriented fire safety concepts and provide fire protection certificate with the help of many years of versatile experimental investigations and the application of recognized engineering methods, such as fire simulations, smoke tests, fire tests. Especially when the implementation of conventional measures is not effective or economically not required, IFAB can develop compensatory measures and establish the approvability. In doing so, the technical/technological solution approaches are worked out and the foundations are laid for the subsequent planning processes of all service phases.

Our employees are recognized experts in their field. This enables IFAB to evaluate fire safety concepts and planning, fire risk analyses and proof of effectiveness as an independent third party.


To prove the effectiveness and viability of exceptional fire protection solutions, experience and profound knowledge of fire processes and the interaction of the various measures of plant engineering, organizational and defensive fire protection are required. IFAB uses recognized engineering methods such as calculation methods, simulations and realistic fire tests to provide proof in individual cases for special fire safety concepts" and solutions.


FIRE AND SMOKE TESTS

IFAB is an accredited test laboratory according to DIN EN ISO/IEC 17025:2018-03 for the performance of fire tests as proof of effectiveness of water-based fire fighting systems. This includes the recording of the measured variables temperature, system pressure of the fire fighting systems or extinguishing systems and gas concentrations (oxygen as well as fire gases carbon monoxide and carbon dioxide). The real fire tests and the measurements are carried out in accordance with valid standards and guidelines of IMO, FM, CEN, DIN, VdS for buildings and industrial buildings. Other measured variables (visibility, flow velocities of air and media, gas concentrations, humidity, etc.) required by the standards and norms are recorded using the mobile IFAB measuring equipment. Heat release rates are determined in real time using recognized calculation methods. The following standards and guidelines have been applied for standardized fire tests so far:

Richtlinienr.

Bezeichnung der Richtlinie

DIN CEN/TS 14972:2011-09*

Fixed firefighting systems - Fine spray extinguishing systems - Planning and installation

Attachment A.1*

Test method flammable liquids

Attachment A.2*

Test method Fire test for cable ducts

Attachment F*

Fire test procedure for certain areas of use of the medium fire hazard class OH3

EN 14972-1-2019

Fine spray extinguishing systems - Part 1: Design, installation, inspection and maintenance

DIN EN 14972-3:2021

Fixed firefighting systems - Water mist systems - Part 3: Test report for offices, schools and hotels for automatic nozzle systems

DIN EN 14972-8:2020

Fixed firefighting systems - Fine spray extinguishing systems - Part 8: Test report for machines in enclosures larger than 260 m³ for open nozzle systems

DIN EN 14972-9:2020

Fixed firefighting systems - Fine spray extinguishing systems - Part 9: Test report for machines in enclosures up to 260 m³ for open nozzle systems

DIN EN 14972-10:2021

Fixed firefighting systems - Fine spray extinguishing systems - Part 10: Fire test report for atrium protection with side wall nozzles for open nozzle systems

DIN EN 14972-14:2021

Fixed firefighting systems - Water mist systems - Part 14: Fire test report for combustion turbines in enclosures larger than 260 m³ for open nozzle systems

DIN EN 14972-15:2021

Fixed firefighting systems - Water mist systems - Part 15: Fire test report for combustion turbines in enclosures up to 260 m³ for open nozzle systems

DIN EN 14972-16:2019

Fixed firefighting systems - Fine mist extinguishing systems - Part 16: Fire test report for industrial large-scale open nozzle fine mist extinguishing systems

IMO Resolution MSC 265 (84):2008-05*

Addendum to the revised guidelines for the approval of sprinkler systems in accordance with those referenced in the SOLAS regulations (Resolution A.800(19)).

FM 5560:2021*

Approval standard for water mist system / fire tests

Attachments: A - N*

Fire tests

VdS OH1 Office: 2010

Test setup and requirements - OH1 (office)

VdS OH1 Hotel: 2012

Test setup and requirements - OH1 (Hotel)

VdS OH1 intermediate floor: 2012

Test setup and requirements - OH1 (intermediate floor and ceilings)

VdS OH3 Bearing: 2011

Test setup and requirements - OH3 (ST1 and ST5/5, sales, storage and technical areas)

VdS cable ducts: 2012

Test setup and requirements - cable ducts

VdS Sidewall nozzle: 2013

Protection of LH and OH areas with sidewall nozzles

VdS chipboard press: 2000

Object protection with fine spray nozzles for particleboard presses

VdS machine protection: 2007

Fire tests for machine protection

VdS OH2 underground garages: 2014

Test setup and requirements - OH2 (underground garages)

IFAB performs smoke tests and fog tests for the above mentioned different applications, such as industrial buildings. Iunnel metro stations or rail vehicles. For this purpose IFAB has the necessary equipment with heat sources, fog generators and smoke generators. This is used to provide evidence for the effectiveness of smoke extraction systems, to investigate the dispersion of smoke gases or to validate the positioning of smoke detectors in rail vehicles. The following standards and guidelines have been applied for smoke tests to date:

Guidelinesr.

Directive name

DIN EN 54

Fire alarm systems

DIN EN 54 – Part 12

Linear detector based on the transmitted light principle

DIN EN 54 – Part 20

Aspirating smoke detector

DIN EN 54 – Part 22

Linear heat detectors

VDI Guideline 6019 Sheet 1

Engineering methods for the design of smoke evacuation from buildings - fire courses, verification of effectiveness.

Test object: smoke extraction

IFAB offers comprehensive support from a single source. Our employees handle the entire process from test conception - through coordination and organization with the test laboratories to the provision of customized measurement technology solutions and including data acquisition and data evaluation.

Together with the customers and, if necessary, authorities and approval bodies, the required documentation and reports for fire tests and smoke tests are prepared.

In addition to the accredited test methods for large-scale fire tests, IFAB as an independent test laboratory also develops application-specific test methods that are not standardized. Applications can be for example:


- Atriums and glass facades,

- Theater aisles and large ceiling heights,

- industrial plants with assembly lines,

- escalators,

- coating plants,

- tunnels, . compact archives,

- Warehouses with plastics,

-fryers,

- high-voltage energy storage systems and

- experimental investigations of design fire scenarios by real fire tests.


For the above mentioned applications IFAB develops with the help of the methods from DIN EN ISO/EC 17025

test concepts, which serve the verification of the effectiveness of the following systems:


- Fire alarm systems,

- Fire fighting systems and extinguishing systems,

- smoke extraction systems and heat extraction systems.


Special attention is paid to the development and dimensioning of the design fires and design fire scenarios. These must be designed in such a way that, on the one hand, they represent the application and, on the other hand, they can be reproduced with sufficient accuracy. These requirements are ensured by the use of suitable surrogate fire loads whose combustion characteristics are precisely known.


Such test series are developed in close consultation with the approval bodies (VdS Schadenverhütung GmbH, TÜV Nord, TÜV Süd or TÜV Rheinland, DEKRA, etc.) so that passing the evaluation criteria defined in the test concept leads to approval for the tested application.